Some installers will not install a 125mm flue/liner system so, if you decide to use 125mm flue/liner, make sure that your installer is willing to install it before you purchase. That would be two 90 degree elbows, or one 90 degree elbow and two 45 degree elbows. Combustible materials should not be placed beneath constuctional hearths unless there is an airspace of at least 50mm or the combustible material is at least 250mm below the top of the hearth. ), About Stove Experience Log Stove Supplier and Installer, Stoves for Smoke Control Areas – Smokeless Zones. In order to do that you need a chimney with a good draw. Building Regulations For Stove Installations. Note the grant is conditional on the registration of the installer with a qualifying body. A pellet stove works with forced draught and the combustion fumes are expelled through an electric fan. Flue diameters for pellet stove and pellet boilers. The exception is for DEFRA Approved stoves which have a 5" flue outlet. There also appears to be evidence that after an initial flurry of enthusiasm over the last ten years that the Northern European pellet industry is contracting. I got excited five years ago when one, notable Danish manufacturer launched a “gravity feed” no electrics, pellet stove. Chimney fire The build up of tar in the chimney (especially when burning wood and bituminous coal) is dangerous as this is the cause of chimney fires. Yes. Do not install a flue damper, and use a ceiling support or fire stop spacer where a vent pipe passes through a ceiling. Rooms away from the stove’s location will need a means of warm air distribution such as a ducted forced-air heating system. If your propety is a Listed Building then permission may or may not be required. . It is unlikely that a property built before 2008 will have an air permeability less than that so the normal procedure will apply to 99% of properties i.e. If you order a flexible liner kit or full twinwall flue sysytem from us it will come with the suitable adaptor to connect to the 5" or 6" enamel pipe. Stovesonline LtdFlightway, Dunkeswell Business ParkDunkeswell, Devon, EX14 4RD, © Stovesonline Ltd. VAT: 801261871, Company: 04636920. The hot flue gases from your stove need to be able to discharge freely and not present a fire hazard, whatever the wind conditions. So the regs recommend a minimum flue size of 150mm for any stove (on which wood could be burnt) unless it is Defra Exempt. I’ve always thought that the best test of a good innovation is to see it copied. Where the flue is not close to the ridge this rule gives the following flue outlet heights: In some cases the requirements may still be met by using flue outlet height lower than the recommended height, whilst in other cases a higher flue outlet height will be needed to give a good draw. More silent than traditional pellet stoves, they have also a longer brazier, where pellets fall down gradually, giving a large and pleasant flame, finally beautiful as the wood-burning one. Be prepared for noise. Until the 1990’s, stoves were not tested for safety, and homeowners had little or no guidance on installation. Local authorities in Scotland regard any woodburning appliance as “Class 1”. Before considering a pellet appliance, please check availability and prices for pellet fuel. Older houses will normally just be exposed brick inside - it is not a legal requirement to line these older chimneys unless they are leaking, but there are often advantages to lining such as increased draw, piece of mind of having a sealed system top to bottom, reduced risk of chimney fire or leakage etc. Please, please, please, look closely at these! Saltfire Stoves Ltd But! If the stove is Defra Exempt and has a 125mm outlet then a 125mm diameter flue may be used. Pellet Stove Installation Requirements Pellet Stoves are typically clean-burning that stoves form one leg of a dual-fuel strategy that is appealing to growing numbers of homeowners concerned with personal independence, sustainability and cost savings. Our flexible chimney liner kits are great value for money and will ensure best performance for your stove. We will sometimes run our chimney design through software to add an extra level of certainty. side or front of house) you may need to check with the local Planning Department. You’ve got to fill it every day, and clean the ash out every few days. Every automatic fuel-feeding device serving a forced-air furnace using solid fuel shall be equipped with the following controls: A clearly labeled device, located near each entrance to the automatic fuel-feeding device floor space and capable or manual operation, for stopping the supply of fuel to the fire grate. It must extend at least 6 inches beyond the front of the stove. These are the recommended flue outlet heights that you can use as a way of meeting the building regulation requirements. Normally for most houses in the UK no extra ventilation is required when installing a stove rated at 5kW or less. Manufacturers of pellet stove vents also have their own requirements for clearances of the vents. The flue for pellet stoves can be installed into an existing masonry chimney usually using an approved chimney liner to keep the old chimney liner from degrading and possibly falling in and blocking the exhaust gases. A roof (or any big object really) creates eddies, swirling patters of air and areas of high and low pressure which can reduce draw. And the stove … Most of our customers fit their stove and or flue liner / system themselves. Do not connect the vent to a vent being used by any other appliance. Most houses built after 1964 should have a concrete/clay inner liner in which case you probably dont need to reline unless there is a problem with your existing system. Pellet Stove Installation Requirements Pellet Stoves are typically clean-burning that stoves form one leg of a dual-fuel strategy that is appealing to growing numbers of homeowners concerned with personal independence, sustainability and cost savings. There are, as yet, few plants to produce the pellet fuel. only stoves greater than 5kW need a vent. The flue termination is measured from the very end of the chimney / flue pipe where the flue gasses discharge. Soot builds up in a chimney over time, especially when burning wood or bituminous coal, and especially when slow burning overnight (do try to avoid overnight burning or 'turning your stove down for the night' - it also results in higher emissions). Despite being pessimistic about the future, and thinly veiling warnings about getting sucked in to the excitement this industry could generate, unfortunately, our telephone has hardly been in it’s cradle recently. The floor protector must be at least the same width and depth of the stove. (Play especially with the cost of oil and the efficiency of oil boilers, then adjust for the current market value of wood pellets and the efficiency of pellet boilers. Lay out a plan on paper, verify all dimensions and have your stove dealer review the plans. Where a new or replacement fixed solid fuel appliance is instaleld in a dwelling, a Carbon Monoxide alarm should be provided in the room where the appliance is located. A stove that attracts grant aid from central government because you are doing your bit in reducing greenhouse gas emissions. The result was house fires that were avoidable. And the availability of imported, high quality fuel, is sporadic, to say the least. Email: enquiries@woodburningstovesdirect.com, The Government issue an Approved Document which contains practical guidance on ways of complying with the Requirements of the Building Regulations -, click here to read the Approved Document J. Tar cannot be removed by the sweeps brush so it can be best to line and insulate your chimney to stop it forming in the first place. The Solid Fuel Association rightly points out that smokeless fuel gives far less chimney deposits than bituminous coal. The second reason is related to safety. Check that your Dyson is working, and the warranty covers the collection of wood dust. No, not normally. For stoves above 5 kW a permanent air vent connected to the outside is required in the same room as the appliance. Follow manufacturer's installation requirements specific to your pellet stove. From time to time the soot becomes dislodged or grows to such a size that it falls down. The automatic fuel-feeding device shall have a control that will maintain a minimum fire and one automatic control to regulate the fuel-feeding device under normal operation. The building regulations say that the flue diameter (or cross sectional area) must not be smaller than the size of the stove outlet, which generally makes great sense. not fitted into en existing fireplace/chimney) the hearth should be a minimum of 840x840mm. You may like to read more about how coal formed and types of coal. These are electrical appliances and should be serviced by suitably qualified, preferably manufacturer trained, electrical engineers. Each model and each manufacturer has potentially different requirements, and it is the responsibility of the installer to follow those requirements. The stove requires a standard 115 volt grounded outlet located where it is not necessary to route the power cord over, under or in front of the stove. Pipe diameters generally range from 4 to 6 inches. As a result, we designed our stoves to be able to connect to either a conventional 5″flue pipe or a 6” balanced (concentric) flue. [Click to enlarge any image] These manuals give examples of pellet stove installation requirements including fire clearances and venting. The vent must also be located not less than 0.3 m above grade level or any surface that may support snow, ice, or debris or be located under a veranda, porch or deck. Buy our quality carbon monoxide alarm here. The exception is for, If you do require a vent, don't worry, they are easy to fit yourself and are not expensive at all -. Most solid fuel appliances in the UK have either a 5" (125mm) or 6" (150mm) flue outlet on the top or rear of the appliance. Taybrite) than less pure alternatives. When installing a Pellet Stove the termination of a sidewall vent serving a pellet-burning appliance shall be located to avoid personal burn injury, fire hazard, and interference with or damage to adjacent properties.